3C12(1) AC90-ISO 150M BK/RD/BU12GN + 12GRD

Description

Description

Standards

  • Product
    CSA C22.2 N° 2556; CSA C22.2 N° 51

AC90 ISO-BX is a 600V armoured cable (interlocked aluminum tape) with 2 or 3 XLPE-insulated solid copper conductors (RW90) + a green XLPE-insulated copper ground (RW90) + a bare copper bond.

Colour coding:

  • 2-conductor constructions: 1 black and 1 white circuit copper conductors, 1 green insulated copper grounding conductor, and 1 bare copper bonding conductor

 

  • 3-conductor constructions: 1 red, 1 black and 1 white circuit conductors, 1 green insulated copper groundeing conductor and 1 bare copper bonding conductor.

2024 CE Code, Part 1 (26th Edition) references:

  • 24-104 Circuits in basic care areas
  • 24-106 Bonding to ground in basic care areas
  • 24-112 Circuits in intermediate and critical care areas
  • 24-114 Bonding to ground in intermediate and critical care areas

Benefits:

  • For use in circuits where an isolated ground is required for minimizing the effects of harmonics and providing a low impedance path to ground.
  • Beneficial for special systems used for critical or sensitive equipment that need to be protected from electrical noise and interference.
  • Reduces the risk of ground loops and common mode voltages.
    • Ground loops can cause errors, distortion, and damage.
    • Common-mode voltages can cause shocks, fires and interference.
  • Improves performance and reliability of sensitive equipment and circuits.
  • Increases the accuracy, quality, lifespan, and safety of sensitive equipment and circuits.
  • Cost-effective alternative to installations in conduit.

Applications:

  • For exposed and concealed wiring in dry locations
  • For use in plenums
  • For use in ventilated, non-ventilated, and ladder-type cable trays
  • For use in branch circuits for computers, cash registers and other electronics
  • For use in branch circuits for patient care areas in healthcare facilities

Features:

  • 90C conductor operating temperature
  • Minus 40C
  • FT4 flame spread rating
  • ST1 limited smoke
  • Halogen Free
  • Lead Free
  • RoHS compliant
  • AG14

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Number of conductors
3
Insulation
XLPE
Conductor Material
Copper

Dimensional characteristics

Dimensional characteristics

Conductor size (AWG)
12
Nominal insulation thickness
0.76 mm
Bare Ground Size (AWG)
12
Cable Diameter
14.2 mm
Approximate Net Weight
247 kg/km
Number of Strands
1
Conductor Diameter (mm)
2.32
Isolated ground conductor cross-section (AWG)
12

Electrical characteristics

Electrical characteristics

Maximum operating voltage
600 V

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C
Minimum installation temperature
-40 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close