Products

1C1000(58) ACWU ACM CT 600V

Nexans ref. 12000994 - Country ref. 651489

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 2457 kg/km
  • Bare Ground Size (AWG): 3/0
  • Cable Diameter: 44.4 mm
  • Conductor Diameter (mm): 26.90
  • Conductor size (AWG): 1000
  • Diameter Over Armour: 41.3 mm
  • Nominal insulation thickness: 2.03 mm
  • Number of Strands: 58

 

1C350(35) ACWU ACM CT 600V

Nexans ref. 12000991 - Country ref. 651422

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 1146 kg/km
  • Bare Ground Size (AWG): 1/0
  • Cable Diameter: 31.4 mm
  • Conductor Diameter (mm): 15.60
  • Conductor size (AWG): 350
  • Diameter Over Armour: 29.2 mm
  • Nominal insulation thickness: 1.65 mm
  • Number of Strands: 35

 

1C500(35) ACWU ACM CT 600V

Nexans ref. 12000992 - Country ref. 651455

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 1462 kg/km
  • Bare Ground Size (AWG): 2/0
  • Cable Diameter: 34.8 mm
  • Conductor Diameter (mm): 18.70
  • Conductor size (AWG): 500
  • Diameter Over Armour: 31.3 mm
  • Nominal insulation thickness: 1.65 mm
  • Number of Strands: 35

 

1C600(58) ACWU ACM CT 600V

Nexans ref. 12000995 - Country ref. 651547

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 1687 kg/km
  • Bare Ground Size (AWG): 3/0
  • Cable Diameter: 38.1 mm
  • Conductor Diameter (mm): 20.70
  • Conductor size (AWG): 600
  • Diameter Over Armour: 35.0 mm
  • Nominal insulation thickness: 2.03 mm
  • Number of Strands: 58

 

1C750(58) ACWU ACM CT 600V

Nexans ref. 12000996 - Country ref. 651554

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 2015 kg/km
  • Bare Ground Size (AWG): 3/0
  • Cable Diameter: 40.6 mm
  • Conductor Diameter (mm): 23.10
  • Conductor size (AWG): 750
  • Diameter Over Armour: 36.8 mm
  • Nominal insulation thickness: 2.03 mm
  • Number of Strands: 58

 

3C 1 ACWU ACM CT 600V

Nexans ref. 12000985 - Country ref. 651307

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 938 kg/km
  • Bare Ground Size (AWG): 4
  • Cable Diameter: 31.7 mm
  • Conductor Diameter (mm): 7.59
  • Conductor size (AWG): 1
  • Diameter Over Armour: 28.9 mm
  • Nominal insulation thickness: 1.4 mm
  • Number of Strands: 8

 

3C 1/0 ACWU ACM CT 600V

Nexans ref. 12000986 - Country ref. 651323

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 1110 kg/km
  • Bare Ground Size (AWG): 4
  • Cable Diameter: 33.5 mm
  • Conductor Diameter (mm): 8.53
  • Conductor size (AWG): 1/0
  • Diameter Over Armour: 31.0 mm
  • Nominal insulation thickness: 1.4 mm
  • Number of Strands: 10

 

3C 2/0 ACWU ACM CT 600V

Nexans ref. 12000987 - Country ref. 651349

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 1415 kg/km
  • Bare Ground Size (AWG): 4
  • Cable Diameter: 35.8 mm
  • Conductor Diameter (mm): 9.55
  • Conductor size (AWG): 2/0
  • Diameter Over Armour: 33.0 mm
  • Nominal insulation thickness: 1.4 mm
  • Number of Strands: 12

 

3C 3/0 ACWU ACM CT 600V

Nexans ref. 12000988 - Country ref. 651364

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 1439 kg/km
  • Bare Ground Size (AWG): 4
  • Cable Diameter: 38.3 mm
  • Conductor Diameter (mm): 10.70
  • Conductor size (AWG): 3/0
  • Diameter Over Armour: 35.8 mm
  • Nominal insulation thickness: 1.4 mm
  • Number of Strands: 19

 

3C 4/0 ACWU ACM CT 600V

Nexans ref. 12000989 - Country ref. 651380

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 1595 kg/km
  • Bare Ground Size (AWG): 4
  • Cable Diameter: 41.9 mm
  • Conductor Diameter (mm): 12.10
  • Conductor size (AWG): 4/0
  • Diameter Over Armour: 38.6 mm
  • Nominal insulation thickness: 1.4 mm
  • Number of Strands: 18

 

3C2(7) ACWU ACM CT 600V

Nexans ref. 12000984 - Country ref. 651281

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 762 kg/km
  • Bare Ground Size (AWG): 6
  • Cable Diameter: 28.7 mm
  • Conductor Diameter (mm): 6.81
  • Conductor size (AWG): 2
  • Diameter Over Armour: 25.9 mm
  • Nominal insulation thickness: 1.14 mm
  • Number of Strands: 6

 

3C250(35) ACWU ACM CT 600V

Nexans ref. 12000990 - Country ref. 651406

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 2510 kg/km
  • Bare Ground Size (AWG): 2
  • Cable Diameter: 45.5 mm
  • Conductor Diameter (mm): 13.20
  • Conductor size (AWG): 250
  • Diameter Over Armour: 42.2 mm
  • Nominal insulation thickness: 1.65 mm
  • Number of Strands: 35

 

3C300(35) ACWU ACM CT 600V

Nexans ref. 12001434 - Country ref. 662135

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 2601 kg/km
  • Bare Ground Size (AWG): 2
  • Cable Diameter: 48.8 mm
  • Conductor Diameter (mm): 14.50
  • Conductor size (AWG): 300
  • Diameter Over Armour: 45.7 mm
  • Nominal insulation thickness: 1.65 mm
  • Number of Strands: 35

 

3C350(35) ACWU ACM CT 600V

Nexans ref. 12001008 - Country ref. 652206

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 3120 kg/km
  • Bare Ground Size (AWG): 2
  • Cable Diameter: 51.6 mm
  • Conductor Diameter (mm): 15.60
  • Conductor size (AWG): 350
  • Diameter Over Armour: 48.3 mm
  • Nominal insulation thickness: 1.65 mm
  • Number of Strands: 35

 

3C4(7) ACWU ACM CT 600V

Nexans ref. 12000981 - Country ref. 651265

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 571 kg/km
  • Bare Ground Size (AWG): 6
  • Cable Diameter: 25.9 mm
  • Conductor Diameter (mm): 5.41
  • Conductor size (AWG): 4
  • Diameter Over Armour: 23.1 mm
  • Nominal insulation thickness: 1.14 mm
  • Number of Strands: 7

 

3C500(35) ACWU ACM CT 600V

Nexans ref. 12000993 - Country ref. 651463

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 4075 kg/km
  • Bare Ground Size (AWG): 1
  • Cable Diameter: 58.2 mm
  • Conductor Diameter (mm): 18.70
  • Conductor size (AWG): 500
  • Diameter Over Armour: 54.9 mm
  • Nominal insulation thickness: 1.65 mm
  • Number of Strands: 37

 

3C6(7) ACWU ACM CT 600V

Nexans ref. 12000980 - Country ref. 651240

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 540 kg/km
  • Bare Ground Size (AWG): 8
  • Cable Diameter: 23.6 mm
  • Conductor Diameter (mm): 4.29
  • Conductor size (AWG): 6
  • Diameter Over Armour: 20.6 mm
  • Nominal insulation thickness: 1.14 mm
  • Number of Strands: 7

 

3C750(58) ACWU ACM CT 600V

Nexans ref. 12001437 - Country ref. 662196

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 5414 kg/km
  • Bare Ground Size (AWG): 1/0
  • Cable Diameter: 72 mm
  • Conductor Diameter (mm): 23.10
  • Conductor size (AWG): 750
  • Diameter Over Armour: 68.3 mm
  • Nominal insulation thickness: 2.03 mm
  • Number of Strands: 58

 

4C 1 ACWU ACM CT 600V

Nexans ref. 12001821 - Country ref. 670484

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 1143 kg/km
  • Bare Ground Size (AWG): 4
  • Cable Diameter: 34.8 mm
  • Conductor Diameter (mm): 7.59
  • Conductor size (AWG): 1
  • Diameter Over Armour: 32.0 mm
  • Nominal insulation thickness: 1.4 mm
  • Number of Strands: 8

 

4C 3/0 ACWU ACM CT 600V

Nexans ref. 12001822 - Country ref. 670487

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 1840 kg/km
  • Bare Ground Size (AWG): 4
  • Cable Diameter: 42.4 mm
  • Conductor Diameter (mm): 10.70
  • Conductor size (AWG): 3/0
  • Diameter Over Armour: 39.4 mm
  • Nominal insulation thickness: 1.4 mm
  • Number of Strands: 18

 

4C 4/0 ACWU ACM CT 600V

Nexans ref. 12001851 - Country ref. 670488

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 2168 kg/km
  • Bare Ground Size (AWG): 4
  • Cable Diameter: 45.7 mm
  • Conductor Diameter (mm): 12.10
  • Conductor size (AWG): 4/0
  • Diameter Over Armour: 42.4 mm
  • Nominal insulation thickness: 1.4 mm
  • Number of Strands: 18

 

4C350(35) ACWU ACM CT 600V

Nexans ref. 12001880 - Country ref. 670490

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 3612 kg/km
  • Bare Ground Size (AWG): 2
  • Cable Diameter: 56.3 mm
  • Conductor Diameter (mm): 15.60
  • Conductor size (AWG): 350
  • Diameter Over Armour: 53.0 mm
  • Nominal insulation thickness: 1.65 mm
  • Number of Strands: 35

 

4C500(35) ACWU ACM CT 600V

Nexans ref. 12001881 - Country ref. 670491

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 4834 kg/km
  • Bare Ground Size (AWG): 1
  • Cable Diameter: 64.5 mm
  • Conductor Diameter (mm): 18.70
  • Conductor size (AWG): 500
  • Diameter Over Armour: 60.4 mm
  • Nominal insulation thickness: 1.65 mm
  • Number of Strands: 35

 

4C750(58) ACWU ACM CT 600V

Nexans ref. 12001438 - Country ref. 662259

  • Packaging: Cut to length (m)
  • Approximate Net Weight: 6885 kg/km
  • Bare Ground Size (AWG): 1/0
  • Cable Diameter: 79.1 mm
  • Conductor Diameter (mm): 23.10
  • Conductor size (AWG): 750
  • Diameter Over Armour: 75.4 mm
  • Nominal insulation thickness: 2.03 mm
  • Number of Strands: 58

 

Description

Description

Standards

  • Product
    CSA C22.2 N° 51

CSA File #LL23462 Class 5811 01 - Cable
CSA File #LL19376 Class 5818 01 - Hazardous Location Cable

 

One to four compact ACM aluminum conductors with low temperature, sunlight resistant (black and colours) EXELENE® cross-linked polyethylene insulation (RW90 XLPE) and bare aluminum bonding wire in multi-conductor cables. Single conductor cables have aluminum concentric bonding wires. Conductor assembly is wrapped and enclosed in an interlocked aluminum armour with an overall low acid gas and low flame spread, sunlight resistant PVC jacket (LAG/LFS) with FT4 and AG14 rating.  LEAD FREE and RoHS compliant.


8 and larger are HL rated for Class I Div 1 & 2 Groups A, B, C & D, Class II Div 1 & 2 Groups E, F & G and Class III Hazardous Locations.

Rated 600 volts. 

Application

  • For exposed and concealed wiring in dry or wet locations and where exposed to the weather. 
  • Nexans cables are marked "SUN RES" for sunlight resistant.
  • For use in ventilated, non-ventilated and ladder type cable trays in wet and dry locations.
  • For direct earth burial (with protection as required by Inspection Authority).
  • For service entrance above or below ground.
  • For use in hazardous locations with approved connectors.
  • Minimum recommended installation temperature minus 40°C (with suitable handling procedures).
  • Maximum conductor temperature 90°C.
  • Limited Smoke Zero Halogen - CSA rated ST1 per CSA 22.2 No. 2556 upon request. Meets the FT4 flame spread test.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor Material
Aluminum
Insulation
XLPE
Insulation Colour
Black

Electrical characteristics

Electrical characteristics

Maximum operating voltage
600 V

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C
Minimum installation temperature
-40 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close