- About Us
- Product Datasheets
- Products Overview
- Services and Solutions
- Newsroom
- Tools & Documents
-
Resources - Webinars
- Resources - Webinars
-
Webinars
- Overview
- Exploring Wire and Cable Used in Data Centres
- Exploring Wire and Cable Used in Healthcare
- Key 2024 CE Code Changes Impacting Wire and Cable
- Industrial Power Cables: Conductors in Shining Armour
- Sustainability In the Wire & Cable Industry
- Copper Demands and Recycling
- Wiring for Canadian Homes - Part 3
- Medium Voltage Solutions for Solar Applications
- Wiring for Canadian Homes - Part 2
- Wiring for Canadian Homes - Part 1
- Cable Manufacturing
- REEL Talk
- ULTRACKER Connected Reels Tracking Solution
- Installations 102
- Installations 101
- Copper & Aluminum: What You Need to Know
- Cables 101
- Raw Material Insights
- Renewable Energy - Wind & Solar Energy Trends
- Emerging Trends for Utility Cables
- Key 2021 Electrical Code Changes Impacting Wire and Cable
- DriveRX® VFD Cables 2.0
- Understanding VFD (Variable Frequency Drive) Cables
- Videos
- Search
- Contact us
- Compare
- Sign in
3C10(7) VFD DRIVERX CU 1KV
Nexans ref. 12001806 - Country ref. 670265
- Packaging: Cut to length (m)
- Approximate Net Weight: 453 kg/km
- Bare Ground Size (AWG): 16
- Cable Diameter: 18.4 mm
- Conductor Diameter (mm): 2.95
- Conductor size (AWG): 10
- Diameter Over Armour: 15.8 mm
- Nominal core diameter: 11.2 mm
- Number of Strands: 7
3C12(7) VFD DRIVERX CU 1KV
Nexans ref. 12001802 - Country ref. 670257
- Packaging: Cut to length (m)
- Approximate Net Weight: 370 kg/km
- Bare Ground Size (AWG): 18
- Cable Diameter: 17.7 mm
- Conductor Diameter (mm): 2.32
- Conductor size (AWG): 12
- Diameter Over Armour: 15.0 mm
- Nominal core diameter: 9.9 mm
- Number of Strands: 7
3C2(7) VFD DRIVERX CU 1KV
Nexans ref. 12001224 - Country ref. 654798
- Packaging: Cut to length (m)
- Approximate Net Weight: 1671 kg/km
- Bare Ground Size (AWG): 10
- Cable Diameter: 32.1 mm
- Conductor Diameter (mm): 7.42
- Conductor size (AWG): 2
- Diameter Over Armour: 29.5 mm
- Nominal core diameter: 21.3 mm
- Number of Strands: 7
3C2/0(18) VFD DRIVERX CU 1KV
Nexans ref. 12001816 - Country ref. 670307
- Packaging: Cut to length (m)
- Approximate Net Weight: 3038 kg/km
- Bare Ground Size (AWG): 10
- Cable Diameter: 43 mm
- Conductor Diameter (mm): 10.64
- Conductor size (AWG): 2/0
- Diameter Over Armour: 39.6 mm
- Nominal core diameter: 29.4 mm
- Number of Strands: 18
3C250(36) VFD DRIVERX CU 1KV
Nexans ref. 12001223 - Country ref. 654814
- Packaging: Cut to length (m)
- Approximate Net Weight: 5030 kg/km
- Bare Ground Size (AWG): 8
- Cable Diameter: 52.9 mm
- Conductor Diameter (mm): 14.61
- Conductor size (AWG): 250
- Diameter Over Armour: 49.6 mm
- Nominal core diameter: 38.5 mm
- Number of Strands: 36
3C350(36) VFD DRIVERX CU 1KV
Nexans ref. 12001818 - Country ref. 670331
- Packaging: Cut to length (m)
- Approximate Net Weight: 6441 kg/km
- Bare Ground Size (AWG): 8
- Cable Diameter: 55.5 mm
- Conductor Diameter (mm): 17.30
- Conductor size (AWG): 350
- Diameter Over Armour: 52.1 mm
- Nominal core diameter: 43.7 mm
- Number of Strands: 36
3C4/0(18) VFD DRIVERX CU 1KV
Nexans ref. 12001817 - Country ref. 670323
- Packaging: Cut to length (m)
- Approximate Net Weight: 4388 kg/km
- Bare Ground Size (AWG): 8
- Cable Diameter: 48.4 mm
- Conductor Diameter (mm): 13.41
- Conductor size (AWG): 4/0
- Diameter Over Armour: 45.0 mm
- Nominal core diameter: 34.9 mm
- Number of Strands: 18
3C500(36) VFD DRIVERX CU 1KV
Nexans ref. 12001819 - Country ref. 670349
- Packaging: Cut to length (m)
- Approximate Net Weight: 8910 kg/km
- Bare Ground Size (AWG): 6
- Cable Diameter: 64.4 mm
- Conductor Diameter (mm): 20.65
- Conductor size (AWG): 500
- Diameter Over Armour: 60.2 mm
- Nominal core diameter: 50.3 mm
- Number of Strands: 36
3C6(7) VFD DRIVERX CU 1KV
Nexans ref. 12001815 - Country ref. 670281
- Packaging: Cut to length (m)
- Approximate Net Weight: 892 kg/km
- Bare Ground Size (AWG): 12
- Cable Diameter: 23.7 mm
- Conductor Diameter (mm): 4.67
- Conductor size (AWG): 6
- Diameter Over Armour: 21.1 mm
- Nominal core diameter: 15.9 mm
- Number of Strands: 7
3C8(7) VFD DRIVERX CU 1KV
Nexans ref. 12001812 - Country ref. 670273
- Packaging: Cut to length (m)
- Approximate Net Weight: 621 kg/km
- Bare Ground Size (AWG): 14
- Cable Diameter: 21.8 mm
- Conductor Diameter (mm): 3.71
- Conductor size (AWG): 8
- Diameter Over Armour: 19.1 mm
- Nominal core diameter: 12.3 mm
- Number of Strands: 7
Description
Description
Standards
-
ProductCSA C22.2 N° 123; CSA C22.2 N° 174
Modern drive technology has enhanced the performance of industrial motors. Decreased switching time of the electronics in Variable Frequency, Pulse Width Modulation or Vector drives, means specialized cables connecting the drive unit and the motor become critical to the performance of these systems. Nexans DriveRx® cable is specially constructed to meet the challenges of modern adjustable speed drive systems.
Drive manufacturers recommend the Nexans cable construction, with the corrugated continuous aluminum sheath and 3 bonding conductors.
The three conductor construction virtually eliminates magnetic fields outside of the cable, so induced voltage from one power cable to another or cross talk to control/instrumentation cables is also reduced. The continuous aluminum sheath (as opposed to interlocked armour) acts as an effective shield for high frequency "noise" that may still be produced and could affect adjacent control and instrumentation cables. This sheath, in combination with the three grounding conductors, also acts as a long-term low resistance path to the ground. This will eliminate standing voltages that may be created on the motor frame and also reduce bearing currents due to this standing voltage or to common mode voltage.
Application
Nexans DriveRx® cable is recommended for industrial, commercial and utility installations including outdoor wet locations. DriveRx® can be installed in tray, conduit or direct buried, strapped to walls or surface mounted. Although DriveRx® can be installed in tray or conduit, mechanical protection is NOT required, as DriveRx® is impact and crush resistant. Cable temperature rating is 90ºC to -40ºC. DriveRx® is flame, oil and UV resistant. PVC jacket rated FT4 and AG14. Certification to standard C22.2 No. 174 allows installation in hazardous locations. LEAD FREE and RoHS compliant.
Limited Smoke Zero Halogen - CSA rated ST1 per CSA 22.2 No. 2556 upon request. Meets the FT4 flame spread test.
Special Handling Considerations – Bending Radius
Nexans DriveRx® cables are easily installed and trained into their final position. The aluminum sheath is corrugated to allow easy bending of the cable, but it is not designed to withstand repeated flexing or excessive bending. During installation or pulling of the cable, the minimum bending radius should be 14x the aluminum sheath diameter. For final training, the minimum bending radius should be 9x the aluminum sheath diameter.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania