10(7) RPVU90 CU BLK 2kV

Description

Description

Standards

  • Product
    CSA C22.2 N° 271; CSA C22.2 N° 38

RPVU90 cables offer exceptional performance, easy installation and long-term reliability for DC and AC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90°C, are UV resistant, may be direct buried, and are certified as CSA type RPVU90.

Application


Nexans RPVU90 cables may be installed indoors or outdoors, in raceways and conduits, both above and below ground, and may be direct buried. Direct buried installations must comply with CE Code Rules 12-012 and 4-004. They are 90ºC, 2 kV rated, and suitable for use in a photovoltaic system.

 

Type RPVU90 cables are for use on the DC and AC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight.

Nexans RPVU90 cables are RoHS Compliant.

Construction


Conductor: 

 

Aluminum: 

  • sizes from #1/0 AWG to 1000 kcmil, stranded
  • compact stranded AA-8000 series aluminum conductor material (ACM) per ASTM B801 Class B or ASTM B836

Copper: 

  • sizes from #14 AWG to 1000 kcmil, solid or stranded
  • bare, stranded annealed per ASTM B8 Class B compressed

 

Insulation:  EXELENE® cross-linked polyethylene (XLPE) insulation per CSA C22.2 No. 271. Sunlight resistant as well as heat, moisture and abrasion resistant.

Options:

  • Class C Stranding (Copper only)


Specifications:

Meets CSA C22.2 No. 271 Photovoltaic Cables

Meets CSA 22.2 No. 38 Thermoset Insulated Wires and Cables

CSA File Number: LL23462 Class 5721 02

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor Material
Copper
Insulation
XLPE
Insulation Colour
Black

Dimensional characteristics

Dimensional characteristics

Approximate Net Weight
69 kg/km
Cable Diameter
6 mm
Conductor Diameter (mm)
2.95
Conductor size (AWG)
10 AWG
Nominal insulation thickness
1.52 mm
Number of Strands
7

Electrical characteristics

Electrical characteristics

Maximum operating voltage
2000 V

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C
Minimum installation temperature
-40 °C

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close